What was found
AFT SERVICE DOOR FWD AND AFT FRAMES HAVE POSSIBLE CORROSION AROUND FASTENER HOLES FOR LINER. REMOVED CORROSION FROM BOTH FWD AND AFT FRAMES IAW SRM 51-21-00-00-02, REV12 MIN THICKNESS NOTED .059", CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-04-910-801 PT 1 & 51-00-06-910-801, PT 1, REV 9. FOUND BLENDS TO BE WITHIN LIMITS IAW RD8/4-52-950 ISSUE 1. ALODINED AND PRIMED IAW RD8/4-52-950, ISSUE 1. COMPLIED WITH TC RD8/4-52-950. WO143293.