What was found
DURING DEPARTURE, RETRACTING LANDING GEAR NOSE GEAR SLOW TO RETRACT, APPROXIMATELY 5 SECONDS AFTER MAIN GEAR LIGHTS EXTINGUISH THEN NOSE GEAR LIGHT EXTINGUISHED. SELECTING GEAR DOWN, NORMAL EXTENSION AND NORMAL TIME. PREFORMED VISUAL INSPECTION OF NLG HYD COMPONENTS, NO LEAKS AND NO DEFECTS NOTED. COMPLIED WITH FUNCTIONAL TEST OF THE LANDING GEAR PRIMARY RETRACTION SYSTEM IAW AMM TASK 32-31-00-720, APPLICABLE STEPS FOR ACFT. FOUND RETRACTION AND EXTENSION TIMES TO BE WITHIN SERVICABLE LIMITS, NO DEFECTS NOTED DURING LANDING GEAR "SWINGS". RETURNED TO SERVICE.