As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING PRE-DEPARTURE WALK AROUND, FOUND AFT SERVICE DOOR HANDLE FWD FLAP COVER AFT SPRING BROKEN. REMOVED FROM SERVICE. UPON FURTHER INSPECTION, SPRING WAS NOT BROKEN, FOUND FLAP DOOR HINGE PIN MIGRATED OUT OF POSITION. RE-SET HINGE PIN AND CHECKED FLAP DOOR FOR OPERATION AND PROPER CLEARANCE, CHECKS GOOD. A/C OK FOR CONTINUED SERVICE.