What was found
CORROSION IN SHEAR CLIP AT FR.88 BETWEEN STR. 27-28R. REMOVED AND REPLACED SHEAR CLIP AT FR 88 BETWEEN STR 27-28R SRM 51-40-08. RESTORED SURFACE PROTECTION. APPLIED TOPCOAT AND C.I.C. SRM 51-23-06
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION IN SHEAR CLIP AT FR.88 BETWEEN STR. 27-28R. REMOVED AND REPLACED SHEAR CLIP AT FR 88 BETWEEN STR 27-28R SRM 51-40-08. RESTORED SURFACE PROTECTION. APPLIED TOPCOAT AND C.I.C. SRM 51-23-06