FLOOR LEVEL LUMINESCENT STRIP PEELING OFF FLOOR OF AIRCRAFT AT ROW 6A/B. REMOVED FROM SERVICE. REPLACED PHOTO LUMINESCENT STRIP @ ROW 6A/B. OPS TEST NORMAL. NO FURTHER DEFECTS. R&R PER AMM 33-50-21-000-801-A/-400-801-A. RETURNED TO SERVICE.