As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY EXIT LIGHT ON CEILING PANEL IS INOP AT FRAME 57-59. REPLACED EMERGENCY CABIN LIGHT ASSY. IAW E175 AMM 33-50-13-000/400-802-A. NO HELP. REF W/O 337760 N/R-00005 FOR WORK PERFROMED. REPLACED ELPU 3. OPS CHECK GOOD. EMERGENCY EXIT LIGHT ON CEILING PANEL AT FR57 TO FR59 OPERATES AS EXPCETED.