Service difficulty report · Aileron Sys · Emb ERJ170200LR

Difficulty date
June 12, 2025
Submitted
June 17, 2025
Operation
Air carrier
Aircraft
N620QX
Make and model
Emb ERJ170200LR
Aircraft serial
17000640
Aircraft time
21,338 hours, 14,126 cycles
Part
Aileron Sys
Condition
Faulted
Stage of operation
AP
How discovered
O
Nature of condition
F
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT 2377. DURING AUTOLAND APPROACH TO 16R AT KSEA, AILERON DEFLECTED TO TO 80 DEGREES TO THE RIGHT NO LOCALIZER FAULT OBSERVED ON APPROACH. AILERONS STAYED UP TO 80 DEGREES RIGHT TO TOUCHDOWN. CONSIDER AUTOLAND UNSUCSESSFUL. REMOVED FROM SERVICE. NO FAULTS ON EICAS. SEARCHED CMC HISTORY FOUND FAULT 22110239PA1. PERFORMED FIM 22-11-00-810-92C-A. CONSIDERED TRANSITORY CONDITION. PERFORMED AUTOPILOT OPS TEST PER AMM 22-11-00-710-802-A, OPS TEST GOOD NO DEFECTS. PERFORMED AUTOPILOT AILERON SERVO OPS TEST PER AMM 22-11-04-710-801-A, OPS TEST GOOD, NO DEFECTS. AIRCRAFT REMAINS CAT III, FLIGHT DECK PLACARD READS CAT III, MAINT CTRL NOTIFIED. RETURNED TO SERVICE. NO PARTS REPLACED.

More about the Emb ERJ 170-200 LR