What was found
R1 DOOR DIFFICULT TO ACUATE ARMING LEVEL. REMOVED FROM SERVICE. MEASURED INITIAL RIGGING VALUES AND MADE ADJUSTMENTS PER AMM 52-41-00-820-801-A. ARMING LEVEL WORKS AS NORMAL FOR R1 DOOR. RETURNED TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R1 DOOR DIFFICULT TO ACUATE ARMING LEVEL. REMOVED FROM SERVICE. MEASURED INITIAL RIGGING VALUES AND MADE ADJUSTMENTS PER AMM 52-41-00-820-801-A. ARMING LEVEL WORKS AS NORMAL FOR R1 DOOR. RETURNED TO SERVICE.