What was found
ENG 2 SHORT DISPATCH, EICAS MESSAGE POPULATED ON ROLLOUT AND TAXI AFTER LANDING. PLACED ON MEL 73-21-01B. MEL CLEARED BY PERFORMING WIRE CHECKS AND CLEANED CONNECTIONS ON FMU IAW LMM 72-00-00-810-808 SUBTASK 72-00-00-810-126 PARA AF. FOUND RESISTANCE ON CONNECTORS J17 & J18 BETWEEEN PINS 6&7 ON EACH TO BE OUT OF LIMITS. R&R FMU ON RT ENG IAW AMM 73-21-03-000/400-801-A. OPS TEST GOOD. FAULTS NO LONGER PRESENT. PLACARDS REMOVED. MTX CONTROL NOTIFIED. CLEAR MEL. RETURNED TO SERVICE.