What was found
CRACK IN FLOORBEAM UNDER FORWARD GALLEY AT STATION 3845 APPROXIMATELY 18 INCHES INBOARD FROM PASSENGER SERVICE EMERGENCY DOOR. REPAIRED IAW FOKKER SRM 53-11-05, PAGE 10, FIGURE 3, SRM 53-02-01 PAGE 7 FIGURE 5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK IN FLOORBEAM UNDER FORWARD GALLEY AT STATION 3845 APPROXIMATELY 18 INCHES INBOARD FROM PASSENGER SERVICE EMERGENCY DOOR. REPAIRED IAW FOKKER SRM 53-11-05, PAGE 10, FIGURE 3, SRM 53-02-01 PAGE 7 FIGURE 5.