What was found
MAINTENANCE FOUND LEVEL 2 CORROSION AT FWD WET AREA FLOORBEAM AROUND GALLEY MOUNT HOLE. MAINTENANCE FABRICATED REPAIR DOUBLER AND INSTALLED IAW ETD 2017-170-096559.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAINTENANCE FOUND LEVEL 2 CORROSION AT FWD WET AREA FLOORBEAM AROUND GALLEY MOUNT HOLE. MAINTENANCE FABRICATED REPAIR DOUBLER AND INSTALLED IAW ETD 2017-170-096559.