What was found
FWD FUSELAGE UNDER FLOOR STRUCTURE AS CROSS BEAM (FRAME 12) BL 0, ANGLE WAS CRACKED. REMOVED AND REPLACED ANGLE IAW SRM 51-41-01 (PSE 53-10-026)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD FUSELAGE UNDER FLOOR STRUCTURE AS CROSS BEAM (FRAME 12) BL 0, ANGLE WAS CRACKED. REMOVED AND REPLACED ANGLE IAW SRM 51-41-01 (PSE 53-10-026)