What was found
CORROSION FOUND ON CF III FLOOR STRUCTURE UPPER SHEET AFT OF RH INBD SEAT TRACK BETWEEN FR 85 AND FR 86. R&R'ED UPPER SHEET AFT OF RH INBD SEAT TRACK BETWEEN FR 85 AND FR 86. IAW EMB 170/175 SRM 51-41-01 AND SRM 51-43-01
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON CF III FLOOR STRUCTURE UPPER SHEET AFT OF RH INBD SEAT TRACK BETWEEN FR 85 AND FR 86. R&R'ED UPPER SHEET AFT OF RH INBD SEAT TRACK BETWEEN FR 85 AND FR 86. IAW EMB 170/175 SRM 51-41-01 AND SRM 51-43-01