What was found
CENTER FUSELAGE III SHEAR CLIP AT FR83 BETWEEN STR 28R AND STR 27R HAD LEVEL 2 CORROSION. SHEAR CLIP WAS REPLACED IAW SRM 51-41-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CENTER FUSELAGE III SHEAR CLIP AT FR83 BETWEEN STR 28R AND STR 27R HAD LEVEL 2 CORROSION. SHEAR CLIP WAS REPLACED IAW SRM 51-41-02.