What was found
LEVEL 2 CORROSION FUSELAGE III SHEAR CLIP AT FR 88 BETWEEN STR 28R AND STR 27R. SHEAR CLIP WAS REPLACED IAW SRM 51-41-02
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION FUSELAGE III SHEAR CLIP AT FR 88 BETWEEN STR 28R AND STR 27R. SHEAR CLIP WAS REPLACED IAW SRM 51-41-02