What was found
FLOOR CROSS BEAM 84 HAS RAZOR SCRATCH AT RBL +22.0". REMOVED RAZOR SCRATCH ALONG FR 84 UPPER CROSSBEAM FLANGE. . FOUND TO BE OUT OF LIMITS REF: EMB SRM 51-10-03. PERFORMED CUT OUT OF THE AFFECTED AREA, LOCATED AND DRILLED REPAIR PARTS FOR CROSSBEAM FRAME 84. INSTALLED AND REPAIR ''L'' ANGLE AND SHIMS ON CROSSBEAM FR84 PER ETD2023-170-008270