What was found
WHILE IN HEAVY CHECK - AFT CABIN BELOW FLOOR SHEARCLIP AT FR 87 IS CORRODED BETWEEN STGR 27R AND 28R.LOCATED/DRILLED UP NEWLY FABRICATED SHEAR CLIP FR 87 STGR 28R-27R AND INSTALLED REF SRM 51-40-08
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WHILE IN HEAVY CHECK - AFT CABIN BELOW FLOOR SHEARCLIP AT FR 87 IS CORRODED BETWEEN STGR 27R AND 28R.LOCATED/DRILLED UP NEWLY FABRICATED SHEAR CLIP FR 87 STGR 28R-27R AND INSTALLED REF SRM 51-40-08