What was found
DURING SCHEDULED NR 2 CHECK, FOUND FWD PRESSURE BULKHEAD LOWER RT ACCESS PANEL STIFFENER CRACKED APPROX 1.0 INCH. REPLACED ACCESS PANEL STIFFENER PER SRM 51-2-9, M-54 NR 73.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED NR 2 CHECK, FOUND FWD PRESSURE BULKHEAD LOWER RT ACCESS PANEL STIFFENER CRACKED APPROX 1.0 INCH. REPLACED ACCESS PANEL STIFFENER PER SRM 51-2-9, M-54 NR 73.