Service difficulty report · Pitot System · Cndair CL6002B19

Difficulty date
March 11, 2012
Submitted
March 14, 2012
Operation
Air carrier
Aircraft
N166PQ
Make and model
Cndair CL6002B19
Aircraft serial
9166
Aircraft time
9,754 hours, 6,921 cycles
Part
Pitot System
Condition
Contaminated
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIR RETURN FOR RUDDER LIMIT FAULT STATUS MESSAGE WITH INTERMITTENT SPOILER/STAB FAULT MESSAGE AFTER WEIGHT OFF WHEELS. PER MOTR COMPLIED WITH CONTAMINATION REMOVAL OF PITOT STATIC SYSTEM PER CRJ900 AMM 34-11-00, COMPLIED WITH LEAK CHECK OF PITOT STATIC SYSTEM PER CRJ900 AMM 34-11-00, EVERYTHING CHECKED GOOD REMOVED AND REPLACED ISIS IAW AMM 34-12-01 AND PERFORMED PITOT STATIC LEAK CHECK NO LEAK OP/C GOOD.