Service difficulty report · Pump · Cndair CL6002B19

Difficulty date
August 17, 2012
Submitted
August 20, 2012
Operation
Air carrier
Aircraft
N8960A
Make and model
Cndair CL6002B19
Aircraft serial
7960
Aircraft time
18,394 hours, 15,861 cycles
Part
Pump
Condition
Malfunctioned
Location
Hyd System
Stage of operation
AP
How discovered
O
Nature of condition
J
Precautionary procedure
B, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT 4145, RECEIVED GEAR DISAGREE ON GEAR EXTENSION. QRH COMPLETED FOR GEAR UP DISAGREE AND HYD 3 LOW PRESSURE CAUTION GEAR EXTENDED AND LOCKED WITH MANUAL EXTENSION. HYD 3 SHOWED LESS THAT 5 PERCENT FLUID AND ZERO PRESSURE. EMERGENCY DECLARED AND COMPLETED NORMAL LANDING. REPLACED LEFT HYDRAULIC PUMP NR 3A IAW AMM 29-12-03. REPLACED RIGHT HYDRAULIC PUMP NR 3B IAW AMM 29-12-03. OPS AND LEAK CHECKED GOOD. BLEED HYDRAULIC SYSTEM NR 3 IAW AMM 29-10-00. COMPLETED INSPECTION OF HYDRAULIC SYSTEM NR 3 IAW AMM 05-51-34. COMPLIED WITH PA 05-018G. GEAR DISAGREE CAUSED BY HYDRAULIC SYSTEM NR 3 FLUID LOSS. ALL CHECKED GOOD.