Service difficulty report · Fan · Cndair CL6002D24

Difficulty date
March 25, 2015
Submitted
March 27, 2015
Operation
Air carrier
Aircraft
N605LR
Make and model
Cndair CL6002D24
Aircraft serial
15160
Aircraft time
17,319 hours, 10,968 cycles
Part
Fan
Condition
Malfunctioned
Location
Lavatory
Stage of operation
AP
How discovered
O
Nature of condition
J
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON 10 MILE FINAL, HAD A SMOKE AFT LAVATORY WARNING. WE COMPLETED THE NON-NORMAL CHECKLIST & LANDED NORMALLY. THERE WAS NO EVIDENCE OF SMOKE OR FIRE. PULLED 7 CB'S AS DIRECTED BY THE CHECKLIST 1B8, 2D8, 2M9, 2M10, 2D5 & 2M5. R & R LAVATORY EXHAUST FAN IAW AMM 21-23-93. PERFORM OPERATIONS CHECK. OPERATIONS CHECKED NORMAL. OK FOR SERVICE. DURING OPERATIONS CHECK NO INDICATION OF SMOKE IN THE LAVATORY.