What was found
LEFT LE OF RUDDER CHAFED AT TOP ON PANEL 327CL. DRILL NEW PANEL FASTENER HOLES IAW 51-40-11. PANEL TO BE INSTALLED ON OPERATION 192. BLENDED CHAFE ON LT LE RUDDER SKIN IAW SRM 55-41-01 BETWEEN STATION 151.51 & 136.90 WITHIN LIMITS. DEPTH .001"-.0085" BLENDS 1) L 3.3" W .45" 2) L3.9" W.9" 3) L3.1"W.2" 4) 1.0"W.2" 5) L1.4"W.2" 5) L1.4"W.18" 6) L1.25"W.28" 7) 1.1"W.5"