As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EN-ROUTE HYD 3 HI TEMP CAUTION POSTED, RAN NON-NORMAL CHECKLIST, SYS 3 PSI DROPPED TO 0 PRIOR TO LANDING. TURNED 3A 3B ON IAW NON-NORMAL CHECKLIST & PSI BACK TO NORMAL. R & R NR 3 HYD RESERVOIR IAW AMM 29-12-30. OPERATIONS & LEAK CHECKED GOOD AT THIS TIME. HYD PRESS & TEMP REMAINED ON NORMAL RANGE. SEE NON-ROUTINE CARD 532062 FOR WORK PERFORMED. ACFT OF FOR SERVICE AT THIS TIME, PN ON OFF 960450-1 SN OFF 807 SN ON 0028.