What was found
DURING WALK AROUND FOUND BULB OUT AND LENS ASSEMBLY BROKEN ON EXTERIOR EMERGENCY LIGHTS. REMOVED AND REPLACED BOTH EMERGENCY LIGHT BULB AND LENS ASSEMBLY IAW AMM 33-51-15. REMOVED AND REPLACED LENS AS REQUIRED. OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING WALK AROUND FOUND BULB OUT AND LENS ASSEMBLY BROKEN ON EXTERIOR EMERGENCY LIGHTS. REMOVED AND REPLACED BOTH EMERGENCY LIGHT BULB AND LENS ASSEMBLY IAW AMM 33-51-15. REMOVED AND REPLACED LENS AS REQUIRED. OPS CHECK GOOD.