What was found
CORROSION FOUND ON THE FLOORBEAM BS 280. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-06, & 51-42-13.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON THE FLOORBEAM BS 280. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-06, & 51-42-13.