What was found
FLOOR LIGHTING IS OUT ROW 8-10. PERFORMED VISUAL INSPECTION OF EMERGENCY LIGHT STRIP AT 9-10 C/D, FOUND STRIP CONNECTOR DISCONNECTED. ATTACHED, OPS CHECKED IAW AMM 33-51-00. OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR LIGHTING IS OUT ROW 8-10. PERFORMED VISUAL INSPECTION OF EMERGENCY LIGHT STRIP AT 9-10 C/D, FOUND STRIP CONNECTOR DISCONNECTED. ATTACHED, OPS CHECKED IAW AMM 33-51-00. OK FOR SERVICE.