What was found
AFTER NDT INSPECTION, CRACK WAS FOUND ON FLOOR BEAM STA FS=274 AND RBL=12 IN REF. EO R53581 STEP 23(C) (CPIL). COMPLETE: SUMMARY OF NRC 00360 FLOOR BEAM STA FS=274 AND RBL=12 WAS REPAIRED PER EO R53212 REV ORIGINAL
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER NDT INSPECTION, CRACK WAS FOUND ON FLOOR BEAM STA FS=274 AND RBL=12 IN REF. EO R53581 STEP 23(C) (CPIL). COMPLETE: SUMMARY OF NRC 00360 FLOOR BEAM STA FS=274 AND RBL=12 WAS REPAIRED PER EO R53212 REV ORIGINAL