What was found
DURING REINSPECT OF THE LH WING PLANK ACCESS HOLE 550CB NOTED INDICATIONS AROUND THE CIRCUMFERENCE OF THE ACCESS HOLE LANDING 75% FULL SCREEN HEIGHT. FAILING NDT AREAS MARKED ON A/C. REPAIRED FUEL PANEL WING PLANK ACCESS HOLE 550CB IAW REO 601RX57-21-3020 DATED 2019-05-01 REV--.