What was found
AWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORT IN STA. FS= 346 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX) SUMMARY:CORROSION LEVEL. 2. PROTECTION PLATE SUPPORT IN STA. FS= 346 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX) WAS MEASURED AND FOUND THE FOLLOWING DIMENSIONS; ORIGINAL THICKNESS. 0.063" DEPTH: 0.033" THEREFORE IS OUT LIMITS PER SRM.