Service difficulty report · Selector Valve · Cndair CL6002B19

Difficulty date
July 24, 2019
Submitted
July 25, 2019
Operation
Air carrier
Aircraft
N8943A
Make and model
Cndair CL6002B19
Aircraft serial
7943
Aircraft time
23,842 hours, 23,687 cycles
Part
Selector Valve
Part number
750005000
Part serial
0602
Condition
Malfunctioned
Location
Mlg
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER T/O RWY 21L WE GOT GEAR DISAGREE WARNING MESSAGE, ALONG WITH A/SKID INBD AND PARK BREAK SOC CAUTION MESSAGE MAIN LANDING DID NOT RETRACT WITHIN 6 SEC. FOLLOWED QRH CYCLE THE GEARS DOWN AND UP UNFORTUNATLEY NO FIX. HEAVY LANDING RWY 22L WITH RATE OF DECENT RATE OF LESS THAN 100'FT. REMOVED AND REPLACED LANDING GEAR CONTROL HANDLES IAW AMM 32-31-01. NO FIX. REMOVED AND REPLACED MLG SELECTOR VALVE IAW AMM 32-32-10. PERFORMED FUNCTIONAL TEST OF THE LANDING GEAR EXTENSION AND RETRACTION SYSTEM IAW AMM 32-0-00. OPS CHECK GOOD. SEE CONTINUATION CARDS 121153 AND 121154 FOR MORE DETAILS. P/N OFF/ON: 7-4502-5 S/N OFF:1586 S/N ON: 1711 P/N OFF/ON: 750005000 S/N OFF: 0141T S/N ON: 0602.