What was found
ON THE APPROACH INTO KTYS CREW OBSERVED L MAIN EJECTOR, L ENGINE FLAME OUT CAUTION MSG'S BOTTLE ARMED PUSH TO DISCHARGE ILLUMIATED ON GLARES- HEILD L ENGINE DID FLAMEOUT TEMPORARILY BUT RESTARTED ON ITS OWN, ALL MSGS CLEARED AS WELL.
CLEANED COLLECTOR TANKS IAW AMM 51-26-00 R/R LH AND RH ENGINE FUEL FILTERS REF NRCC 130490 R/R APU FUEL FILTER RED NRCC 130488 SEE NRWC 7603- 65 FOR FURTHER MAINTENANCE ACTIONS. COMPLIED WITH WORK SCOPE ISSUED BY MOTR DEPARTMENT PERFORMED POWER ASSURANCE RUNS IAW AMM 71-00-00. OPER- ATIONAL CHECK GOOD.