What was found
PAX DOOR AFT WEB BOTTOM FASTNER FLANGE FOR STEP PNL 832 BT IS CORRODED. LOCATED AND DRILLED NEW PAX DOOR AFT STAIR WEB AND INSTALLED SUPPORT ANGLES ONTO NEW WEB IAW SRM 51-40-11-001- 001-A01 AND 51-42-06-001-001-A01 REV 38.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PAX DOOR AFT WEB BOTTOM FASTNER FLANGE FOR STEP PNL 832 BT IS CORRODED. LOCATED AND DRILLED NEW PAX DOOR AFT STAIR WEB AND INSTALLED SUPPORT ANGLES ONTO NEW WEB IAW SRM 51-40-11-001- 001-A01 AND 51-42-06-001-001-A01 REV 38.