What was found
SERVICE DOOR SURROUND STRUCTURE, INTERCOSTAL CORRODED BETWEEN FS 295 AND FS 333 AT STGR 20R. - REMOVED INTERCOSTAL AT RBL27 FOR ACCESS & INSTALLED, REMOVED & INTERCOSTAL AT 20R IAW CRJ 900 SRMS 51-42-21-001-001-A01, 51-42-06-001-001-A01, 51-40-11-001-001-A01, 51-25-00-001-001-A01 & INSTALLED SCREWS IAW CRJ 900 SRM 51-41-02-001-001-A01. WVAC EMP STAMP