What was found
FOUND RH FLOOR BEAM JUST FWD OF FS280 ABOVE 6 FASTENER HOLES HAS INDICATION NOTED .500 LONG 100% FSH FAILED NDT INSPECTION. C/A: REMOVED & REPLACED FLOOR BEAM IAW CRJ 900 SRM 53-11-43-201-003-A01 REPAIR TYPE 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND RH FLOOR BEAM JUST FWD OF FS280 ABOVE 6 FASTENER HOLES HAS INDICATION NOTED .500 LONG 100% FSH FAILED NDT INSPECTION. C/A: REMOVED & REPLACED FLOOR BEAM IAW CRJ 900 SRM 53-11-43-201-003-A01 REPAIR TYPE 4.