What was found
MULTIPLE EMERGENCY LIGHTS ON FFOD TEST NOT STAYING LIT.OVERHEAD WING EXIT LIGHT(FWD),OVERHEAD PASSENGER DOOR LIGHT AND LEFT EXTERIOR WING LIGHT OBSERVED TO BRIFELY ILLUMINATE AND THE EXTINGUISH WHEN COMMANDED ON. DEFERRED IAW MEL 33-51-1A.TRANSFERED TO MMO2.MOC NOTIFIED#52547. PLACARD INSTALLED./////R&R LH CENTER EMERGENCY LIGHT BUILB IAW CRJ 200 AMM 33-51-21.OPC ALL EMERGENCY LIGHT IAW CRJ 200 AMM 33-51-00.OPC GOOD AT THIS TIME. MMO2 UPDATED. PLACARD REMOVED. MOC NOTIFIED #4488.