What was found
LBL27 FLOOR BEAM IS CORRODED BETWEEN F.S. 985 TO F.S. 1000. - COMPLIED WITH REPAIR OF LBL27 FLOOR BEAM IAW CRJ900 SRM 53-00-41-201-001-A03 PERFORMED EDDY CURRENT ON FLOOR BEAM IAW CRJ900 SRM 53-00-41-201-001 A03 STEP 5B3 REMOVED AND INSTALLED SEAT TRACK IAW CRJ900 AMM 53-00-49-000/400-801-A11 DRILLED, LOCATED AND TRIMMED TO FIT LBL27 FLOOR BEAM BETWEEN FS 985-FS 1056 IAW CRJ900 SRM 53-00-41-201-001-A03 INSTALLED SECTION OF FLOOR BEAM BETWEEN FS 977 TO FS 1056 IAW CRJ900 SRM 53-00-41-201-001-A03 APPLIED PAINT AND CIC IAW CRJ900 SRM 51-25-16-001-001-A01