What was found
FWD EXTERNAL FUSELAGE SUPPORT STRUCTURE IS CORRODED AT LOWER FLANGE AT FS 661.62. REPLACED FWD SUPPORT STRUCTURE SPLICE PLATE IAW CRJ 900 SRM 51-42-06-001-001-A01 AND 51-42-15-001-001-A01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD EXTERNAL FUSELAGE SUPPORT STRUCTURE IS CORRODED AT LOWER FLANGE AT FS 661.62. REPLACED FWD SUPPORT STRUCTURE SPLICE PLATE IAW CRJ 900 SRM 51-42-06-001-001-A01 AND 51-42-15-001-001-A01.