Service difficulty report · Angle · Cndair CL6002D24

Difficulty date
May 23, 2024
Submitted
July 3, 2024
Operation
Air carrier
Aircraft
N582CA
Make and model
Cndair CL6002D24
Aircraft serial
15171
Aircraft time
34,949 hours, 24,498 cycles
Part
Angle
Part number
SH6703228515
Condition
Corroded
Location
Bs 379-394 S21r
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

"WATER WASTE SERVICE DOOR SURROUND DIAPHRAGM P/N SH670-32285-13 IS CORRODED ON OUTER SURFACE BETWEEN FS379.00 AND FS394.00, STR 21R. INSTALLED NEW SERVICEABLE SURROUND DIAPHRAGM PN SH670-32285-15 IAW CRJ 900 SRM 51-42-06-001-001-A01.EVALUATE AND BLEND CORROSION ON WASTE WATER SERVICE DOOR UPPER SURROUND DIAPHRAGM. CORRECTIVE ACTION: BLENDED CORROSION ON UPPER SURROUND DIAPHRAGM PN SH670-32285 WITH A NOMINAL THICKNESS OF 0.080"" AND MAX ALLOWABLE LIMIT OF 0.008"" IAW CRJ 900 SRM 51-21-06-001-001-A01 AND SRM 53-21-23-101-005-A02. MRT IS 0.052"" IS OUT OF LIMITS AND WILL REQUIRE REPLACEMENT. TOOL USED WVACT 203808 CAL DUE 30SEP24.LOCATE AND DRILL NEW SERVICEABLE SURROUND DIAPHRAGM PN SH670-32285-15. CORRECTIVE ACTION: LOCATED AND DRILLED NEW SERVICEABLE SURROUND DIAPHRAGM PN SH670-32285-15 IAW CRJ 900 SRM 51-40-11-001-001-A01. INSTALL 6 DOME NUTPLATES AROUND HOLE FOR VENT LINE ON SURROUND DIAPHRAGM. CORRECTIVE ACTION: INSTALLED 6 DOME NUTPLATES AROUND HOLE FOR VENT LINE ON SURROUND DIAPHRAGM IAW CRJ 900 SRM 51-42-06-001-001-A01. APPLY ""VENT"", ""DRAIN"", AND ""T-HANDLE"" DECALS. CORRECTIVE ACTION: INSTALLED ""DRAIN"" DECAL P/N: S7640-1 AND ""T-HANDLE"" DECAL P/N: S30318-1 IAW CJ900 AIPC 11-20-02-01M. LINE 4A CAN NOT BE SIGNED OFF TO A IPC CORRECTIVE ACTION: WORK PERFORMED IN TASK 4A IAW CRJ 900 AMM 20-60-04-400-801-A01.APPLY ""VENT"" DECAL. CORRECTIVE ACTION: INSTALLED VENT DECAL P/N S7201-1 IAW CRJ 900 AMM 20-60-04-400-801-A01.APPLY EDGE SEALANT, AND SEAL AROUND DOME NUTPLATES. CORRECTIVE ACTION: SEALED REWORKED AREAS AND DOME NUTPLATES IAW CRJ900 SRM 51-23-00-001-001-A01.APPLY PROTECTIVE SURFACE FINISH. CORRECTIVE ACTION: APPLIED PROTECTIVE SURFACE FINISH IAW CRJ 900 SRM 51-25-16-001-001-A01.303.6 LINE 5 IS INCORRECT CORRECTIVE ACTION: CORRECTED LINE 5 OF 303.6INTERCOSTAL LOCATED AT FS 349-364 AT RBL 37 WAS REMOVED FOR ACCESS IAW CRJ 900 SRM 51-42-21-001-001-A01. CORRECTIVE ACTION: REINSTALLED INTERCOSTAL LOCATED AT FS 349-364 AT RBL 37 IAW CRJ 900 SRM 51-42-21-001-001-A01.CABIN PRESSURIZATION LEAK TEST REQUIRED. CORRECTIVE ACTION: COMPLIED WITH LEAK TEST OF WASTE WATER SERVICE DOOR UPPER SURROUND DIAPHRAGM IAW CRJ900 AMM 52-00-00-790-801 (A01). LEAK TEST GOOD AT THIS TIME."