What was found
"FS 280 RH CROSSBEAM IS CORRODED AT RBL 9. FOUND FS 280 RH CROSSBEAM TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS GIVEN. REQUIRES REPLACEMENT. INSTALLED ALL FASTENERS FROM FS 280 RH CROSSBEAM IAW CRJ900 SRM 51-42-06-001-001-A01, 51-42-13-001-001-A01, 51-42-21-001-001-A01, AND 51-42-22-001-001-A01. INSTALLED RH FS 280.00 CROSSBEAM P/N: CC670-34094JP-2S, IAW CRJ900 SRM 51-42-06-001-001-A01. CRJ900 SRM 51-42-13-001-001-A01. AND CRJ900 SRM 51-42-21-001-001-A01. LOCATED AND DRILLED NEW SERVICEABLE RH FS280 CROSSBEAM P/N CC670-34094JP-2S IAW CRJ900 SRM 51-40-11-001-001-A01. LOCATED AND DRILLED J ANGLE AREA ON RH 280 CROSSBEAM IAW CRJ 900 SRM 51-40-11-001-001-A01.ATTACHED FOR 303.6 AS REQUIRED NOTES"