What was found
"L/H WING FLAP PANELS 584LB, 584JB, 584EB, AND 584GB HAVE CHAFFING AND PAINT DAMAGE. BLENDED AND GRIDDED CHAFED AREA ON 4EA L/H WING FLAP ACCESS PANELS 584LB, 584JB, 584EB, AND 584GB IAW CRJ900SRM 51-12-00-001-001-A01. PANELS 584LB, 584EB AND 584GB FOUND TO BE WITHIN LIMITS. PANEL 584JB FOUND TO BE OUT OF LIMITS. 584LB ORG. .090"", REMAINING .086"", ALLOWABLE .015"", REMOVED .004"". 584EB ORG. .090"", REMAINING .087"", ALLOWABLE .015"", REMOVED .003"". 584GB ORG. .090"", REMAINING .078"", ALLOWABLE .015"", REMOVED .012"". 584JB ORG. .090"", REMAINING .072"", ALLOWABLE .015"", REMOVED .018"" IAW CRJ900 SRM 57-52-01-101-001-A01. RESTORED FINISH IAW CRJ-900 SRM 51-25-06-001-001-A01 AND SRM 51-25-16-001-001-A01."