What was found
"GUSSETS ON L/H AND R/H SIDES COMMON TO FWD ""J"" ANGLE AND COCKPIT FLOORBOARD HAS ELONGATED HOLES. REMOVED, LOCATED AND DRILLED, INSTALLED NEW GUSSETS P/N CC670-33467-1, CC670-33467-2 IAW CRJ 900 SRM 51-40-11-001-001-A01, 51-42-06/21-001-001-A01. RESTORED SURFACE FINISH IAW CRJ SRM (TR51-0068) 51-21-16-001-001-A01."