What was found
"FOUND 2EA BUSHING LUGS LABELED ""C"" AND ""F"" TO BE PREVIOUSLY OVERSIZED ON R/H AILERON COMPLIED WITH STEP #6 (5) & #6 (6) OF BOMBARDIER REO 670-57-61-107 REV. -B DATED 2019-01-14. STEP #6 (5) - FABRICATED (QTY. 2) O/S R/H AILERON CENTER HINGE BUSHINGS LABELED ""C"" & ""F"" (P.N. S10009-225Y) USING MATERIAL AMS5659 (5-35803). STEP #6 (6) - ENSURE FLANGE DIAMETER. O/S C/W LPI OF R/H AILERON CENTER HINGE BUSHINGS LABELED ""C"" & ""F"" REQUIRE NDT PER STEP #6 (5-I) OF BOMBARDIER REO 670-57-61-107 REV. -B DATED 2019-01-14. C/W STEP #5-II OF BOMBARDIER REO 670-57-61-107 REV. -B DATED 2019-01-14 (CAD PLATE). CARD GENERATED FOR FABRICATION ONLY. REFERENCE TASK CARD 900-27-900-912_CC670 C1 HR00486623 FOR INSTALLATION OF BUSHINGS"