What was found
FRAME AT FS 379.00 IS CORRODED BETWEEN STGR 24R TO 20R. LOCATED AND DRILLED NEW SERVICEABLE FRAME P/N: SH670-32118-1S, AT FS379 BETWEEN STR 20R TO STR25R IAW CRJ-700 SRM 51-40-11-001-001-A01. INSTALLED NEW SERVICEABLE FRAME FS 379 P/N: SH670-32118-1S, BETWEEN STR20R TO STR25R, IAW CRJ-700 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01. INSTALLED SAME SERVICEABLE FRAME SPLICE AT FS379 STR20R, IAW CRJ-700 SRM 51-42-06-001-001-A01. INSTALLED UPPER ANGLE AT FS 379 FWD FACE BETWEEN STR21R TO STR 23R, IAW CRJ-700 SRM 51-42-06-001-001-A01. INSTALLED REINFORCING ANGLE ON FRAME AT FS379 BETWEEN STR20R TO STR25R, IAW CRJ-700 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01. APPLIED PAINT AND EDGE SEAL ON REPAIRED AREA IAW CRJ700 SRM 51-23-001-001-A01 AND 51-25-16-001-001-A01.