What was found
STRINGER 22R BETWEEN F.S.333 TO F.S.349 IS CORRODED. EVALUATED DAMAGE FOUND TO BE 100% MATERIAL LOSS, FOUND P/N SH670-31379-1 TO BE OUT OF ALLOWABLE LIMITS IAW CRJ700 SRM 53-21-03-101-006-A01 REQUIRES REPLACEMENT INSTALLED NEW SERVICEABLE STRG SPLICE FROM FS 333 AND STR 22R IAW CRJ700 SRM 51-42-06-001-001-A01 INSTALLED STGR CLEAT AT FS 349.00 STGR 22R IAW CRJ700 SRM 51-42-06-001-001-A01. INSTALLED CLEAT AT STR 22R AND FS 333 IAW CRJ700 SRM 51-42-06-001-001-A01. REMOVED DAMAGED STGR 22R BETWEEN FS 333.00 AND FS 349.00 IAW CRJ700 SRM 51-42-06-001-001-A01. INSTALLED NEW STGR 22R P/N: SH670-31397-1S BETWEEN FS 333.00 AND FS 349.00 IAW CRJ700 SRM 51-42-06-001-001-A01. LOCATED AND DRILLED NEW STGR 22R P/N:SH670-