What was found
FOUND RT WING AILERON LUGS LABELED E & F TO BE PREVIOUSLY OVERSIZED. COMPLIED WITH STEPS NR 1, 4, 5, & 7 OF REO 690-57-51-456 REV. FABRICATED O/S RT AILERON BUSHING. HFEC PERFORMED IAW REO 690-57-51-456 REV -, NO INDICATIONS NOTED. C/W STEP 2 OF REO 690-57-51-456, REV --, BORES ARE DAMAGE FREE. C/W LPI ON NEWLY FABRICATED BUSHINGS IAW REO 690-57-51-456 REV -- STEO 7.B. NO INDICATION NOTED. APPLIED BRUSH CAD-PLATING TO NEW BUSHINGS IAW STEP NR 7(C) OF REO 690-57-51-456 REV. --. INSTALLED FABRICATED BUSHINGS ON RT WING AILERON LUGS LABELED E & F IAW AMM 20-31-00-400-801-A01.