What was found
"CORROSION ON INTERCOSTAL (3E/A) BTW FS 364 TO FS 369 STGR 26L TO STGR 25R CORROSION ON INTERCOSTAL (3E/A) BTW FS 364 TO FS 369 STGR 26L TO STGR 25R WAS REMOVED PER CRJ 900 SRM 51-21-06-001-001-A01 AND EVALUATED INTERCOSTALS (2EA'S) BTW FS 364 TO FS 369 STGR 26RH ORIGINAL THICKNESS IS 0.063"" IN AND MINIMUM REMAINING THICKNESS IS 0.060""IN AND STGR 27 WAS ACCOMPLISHED WITH ORIGINAL THICKNESS IS 0.080"" IN AND MINIMUM REMAINING THICKNESS IS 0.075""IN THEREFORE THEY ARE WITHIN LIMITS PER CRJ-900 SRM 53-21-23-101-003-A02 AND INTERCOSTAL (P/N: SH670-32075-3) 27LH WAS REPLACED BY EXCESSIVE CORROSIÏ¿½N PER CRJ 900 SRM 51-42-21-001-001-A01 AND SRM 51-42-06-001-001-A01 "