What was found
CORROSION ON FLOOR SUPPORT ANGLE AND ANGLES ON FS 280 BTW RBL12 TO LBL 12 AT PASSENGER FLOOR. CORROSION ON FLOOR SUPPORT ANGLE AND ANGLES ON BS 280 BTWN RBL12 TO LBL 12 AT PASSENGER FLOOR WAS REMOVED IAW SRM 51-21-06-001-001-A01 AND FLOOR SUPPORT BS 280 BTW RBL12 TO LBL 12 WAS EVALUATED OUT LIMITS IAW SRM 51-10-06-001-001-A01 THEREFORE WAS REPLACED IAW SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01 & ANGLES FS 280 BTW RBL12 TO LBL 12 WERE EVALUATED WITHIN LIMITS IAW SRM 53-00-00-101-001-A01.