What was found
LEFT AFT OVERWING EMERGENCY EXIT DOOR, UPPER FORMER WAS CRACKED AT SWITCH TARGET. PERFORMED LPI OF LT AFT EMERGENCY EXIT FORMER AT LUG IAW NDTM PART 1 51-20-008-230-A01. FOUND 1- INCH INDICATIONS NOTED AT LUG, FAILED NDT. PERFORMED PERMANENT REPAIR ON THE LT AFT OVERWING EMERGENCY EXIT UPPER FORMER IAW REO 670-52-21-103, REV -. RESTORED SURFACE FINISH ON LT AFT OVERWING EMERGENCY EXIT UPPER FORMER IAW SRM 51-25-06-001-001-A01, & 51-25-16-001-001-A01.