Service difficulty report · Warning Message · Emb ERJ190100IGW

Difficulty date
August 23, 2017
Submitted
August 25, 2017
Operation
Air carrier
Aircraft
N937TA
Make and model
Emb ERJ190100IGW
Aircraft serial
19000221
Part
Warning Message
Condition
Inoperative
Stage of operation
NR
How discovered
9
Nature of condition
P
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

UPON ARRIVAL, THE PILOT REPORTED, CABIN TEMPERATURE HOT. FLT CTRL NO DISPATCH MESSAGE. MAINTENANCE PERFORMED FAULT ANALYSIS IAW FIM 21-51-00-810-824-A, TESTED THE ADD HEAT VALVE IAW AMM 45-45-00-970-805-A, OBTANING NORMAL RESULTS. PERFORMED FAULT ANALYSIS IAW FIM 27-03-00-810-91Y-A, REPLACED THE P-ACE 3 IAW AMM 27-03-03/400, PERFORMED THE FLIGHT CONTROL RETURN TO SERVICE TEST IAW AMM 27-00-00-070-801-A OBTAINING NORMAL RESULTS. AFTER THOSE MAINTENANCE ACTIONS THE AIRCRAFT WAS RETURNED TO SERVICE