What was found
DURING A MAINTENANCE VISIT FOUND CRACK, FUSELAGE, INTERCOSTAL GOUGED/CRACKED OUT HOLES BETWEEN STA 1420 AND STA 1400 RT, BETWEEN LONGERON 2 RIGHT AND LONGERON 3 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.